To determine Cd of a venturi flume

Object: To determine the Cd of a venturi flume.

Apparatus Required:

  • S-4 Tilting flume consisting of the tilt control device, rotameter, and Venturi flume plates.
Word Image 3310 1

Perspex-sided S4 tilting flume

Theory:

Word Image 3310 2

For a convergence – divergence flume,

Qth

b

h H h1 / 2

(6.1)

When the convergence is sufficiently narrow the flow in it passes through critical phase

2g

1

h  2

3 H1 , and the discharge becomes related to H1 as:

 11 / 2

2g 2

3

Qth = b

H1  3 H

i.eQth = 1.705 b

orQth = 17.05 b

3/ 2

H

1

3/ 2

H

1

(mks units)(6.2)

(cgs units)(6.3)

Approximating H1 to H,

Qac = 17.05 Cd b

H3/2

(6.4)

orCd =

Qac

17.05b H3/2

(cgs units)(6.5)

Procedure:

Observations:

b = 4.7 cm

S. No.

Qac-rota

Qac

= 1000 Qac-rota

H

Q ac

Cd = 17.05×4.7xH 3/2

lit/s

cc/s

Cm

1

2

3

4

5

Aver.

………..

Results & Comments: